In Bulgaria, the fiscal device itself generates the automatic daily financial report. This article helps you check its operation and distinguish device closing from a POS cash shift.
What a Z report closes#
A fiscal shift belongs to the device and its daily totals. A Z report closes that period and resets the daily counters. An X report shows totals without closing the shift.
A POS cash shift separately tracks the float, cash additions, withdrawals and cash on hand. The device’s Z report does not confirm a cash count or replace a handover between staff.
What Bulgarian rules confirm#
Under Article 39(1) of Ordinance N-18, fiscal devices and approved integrated systems (IASUTD) automatically generate a daily financial report at 23:59:59 for a calendar day with sales, reversals or service operations. This applies if no report has been generated yet or further operations occurred after it.
Under paragraph 1a, if the device is off or a receipt is unfinished, the report is generated after power-on or receipt completion, dated to the last operations. A calendar day must not be replaced with a “24 hours from opening” rule.
For fuel ESFP systems, paragraph 1b separately regulates report printing, with an exception for fully self-service sites. Check the applicable rules before extending the general procedure to a petrol station register.
These provisions are supported by the BIM primary source linked below. This article explains the researched rules and product capabilities; it is not a legal opinion.
What the device does itself#
For the Bulgarian version of Daisy Compact M 02, the 2025 manual, page 69, confirms automatic Z reporting. The time is set with system parameter 26 in programming mode, using HHMM. Check the exact procedure for your version with the supplier.
If no further operations occurred after the previous Z, another automatic report is not generated at the end of the day. A computer Z command does not in itself confirm that the timer can be configured from a PC.
Menus and firmware of other models were not checked in this research. A Bulgarian manual does not establish the same capability in Daisy national versions for other countries.
Close the shift remotely#
As of 25 November 2026, general legal permission for an owner or manager to issue a Z report from another location has not been established. Article 39 of Ordinance N-18 governs built-in closing; Annex 1, I.14 concerns remote parameter changes. Neither establishes permission for any Z command sent through a cloud service.
For Bulgarian Daisy devices, protocol V2.0-6/2026 confirms technical command 69: operations 0/1 issue Z, while operation 6 records it in EJT/FM without paper. No separate key confirmation is described in the prepared normal PC mode. Entering that mode, paper handling and errors may require someone on site. This does not confirm support for the entire range in the cenaly.com bridge; Georgian firmware is not interchangeable with Bulgarian firmware.
The remote initiator’s authority, a mandatory name field in Z and local confirmation requirements across models remain unestablished. Command 69 has no initiator-name parameter; the absence of a name in the reviewed minimum Z fields does not authorise substituting the owner for the cashier. Datecs, Tremol, Eltrade, ISL, integrated IASUTD systems and fuel ESFP systems require separate checks. For ESFP, Article 39(1b) and (5) separately govern printing and keeping the register book, with self-service exceptions.
Before closing from outside the premises, confirm the permitted procedure with the approved device’s supplier and, if the legal question remains, with the NRA. A button in the panel does not replace that confirmation. If the outcome is uncertain, check the device’s last Z report first.
What cenaly.com does today#
Software-controlled closing and configuration of the built-in timer through cenaly.com are currently unavailable. Changing the language or domain does not reveal the switch: the location’s country and device capabilities determine availability.
An already connected, supported device can be closed with a manual Z command. The path below does not establish compatibility between every Bulgarian register and the hardware bridge.
Do not rely on an automatic POS cash-shift closure following the device’s built-in Z. Check the fiscal report and cash count separately.
What you need to check#
- The exact model, Bulgarian firmware version and device manual.
- Equipment access for the owner or an authorised member of staff.
- For manual Z from the panel: a supported connection, a running bridge and communication with the register.
- A member of staff who verifies closing results and handles errors.
Checks at your location#
- Check the location’s country, device clock and automatic daily-report mode. For Compact M 02, use the manual for your version; do not copy a parameter number from another model.
- To close a connected register manually, open Hardware → register → “Shift & reports” → “Close shift (Z report)”. Read the confirmation: Z closes the period and cannot be undone.
- Check the successful response, report number and device status. A scheduled time, no error or an X report alone does not prove closing succeeded.
- If the POS “Receipt was not printed” window offers “Take Z and retry receipt”, use it after checking the cause. The receipt is retried only after a successful Z; if the outcome is unknown, first reconcile the device’s documents.
- In the web-POS version with a shift indicator, it depends on bridge data. A warning before blocking requires a known deadline; no warning does not mean the shift can safely remain open.
- Count the cash and complete the POS cash shift using your normal procedure.
If the device is not connected to cenaly.com or its driver is unsupported, close it using the device’s own facilities and the supplier’s instructions.
Cashier and signature on the report#
The cashier details, personal signature and physical-presence requirements specifically for automatic Z have not been established or confirmed by a primary source in the researched materials.
Do not replace the responsible person with an invented name or an “Automatic closing” label. Agree on the required details and report checks with the device supplier and the person responsible for accounting.
Limitations#
- A legal requirement for built-in closing does not prove a particular register’s timer works correctly.
- Configuring the Compact M 02 timer through our bridge has not been confirmed.
- The legality of an external Z schedule without a cashier has not been confirmed by a primary source.
- Specific penalties for a late or empty Z have not been established from a primary source; penalties for failing to issue receipts are not applied here.
Troubleshooting#
| Situation | What to check |
|---|---|
| There is no automatic-closing switch in the panel | This is the current limitation; check the built-in mode with the supplier |
| No new Z appeared at day-end | Whether operations occurred after the previous Z, the device was on and the receipt was completed |
| Manual Z failed | The register message, paper, connection and open receipt; follow your model’s instructions |
| Connection was lost during Z | First check the report number and status on the device; do not retry blindly |
| Z exists but the cash shift is open | Count the cash and close the POS cash shift separately |
Give support the model, firmware, location, error time and last Z number. Do not attach operator passwords.
Frequently asked questions#
Can I enable the timer in cenaly.com?#
Not yet. The device’s built-in mechanism is confirmed, but configuration through our service is not.
Is another Z needed if nothing happened after the first one?#
The described automatic mechanism does not generate another report without further operations. This is not advice to change your register’s manual closing procedure.
Does this work on every Daisy?#
No. The verified manual covers the Bulgarian Compact M 02; other models and national firmware versions need their own checks.
Sources#
BIM: Ordinance N-18, Article 39, paragraphs 1, 1a and 1b; consolidated text including amendments in State Gazette 42/2025.
Daisy Compact M 02: 2025 manual, page 69, parameter 26.