Automatic closing generates a fiscal cash register's Z report at a set time or before the shift reaches its limit. It helps prevent missed closings, but does not count banknotes or replace staff handover. This guide explains how to check availability and what to do if the register already refuses to issue receipts.
Who can use it#
This workflow concerns locations with a connected fiscal cash register — for example, a shop, café or service business where such a register is used. Having POS access or a demo does not establish support for automatic closing. The owner or a staff member with access to the location's hardware settings checks the country, model, national firmware and installed bridge capabilities.
Availability depends on the location's country, not the interface language, website domain or account country. Switching brands does not unlock the setting. Automatic closing is off for existing customers; updating the program does not turn it on.
There are two different methods:
- Through the hardware bridge: the running program on the computer sends a Z command to the register. The computer and register must be powered on and connected to each other.
- The register's built-in mechanism: the register or approved fiscal system generates the report itself. Evidence for this mechanism does not establish permission for external software to issue unattended Z reports.
Availability by country#
This is a snapshot of service availability rules, not a legal opinion. “Not available yet” means there is insufficient basis to enable it in the service; it does not mean the country's law explicitly bans automatic Z reports. “Not applicable” concerns the fiscalisation regime studied, and does not remove sales accounting, record retention or industry requirements. Unknown countries are not enabled either.
| Country | Availability |
|---|---|
| Russia (RU) | Not available yet |
| Georgia (GE) | Not available yet |
| Armenia (AM) | Not available yet |
| Azerbaijan (AZ) | Not available yet |
| Kazakhstan (KZ) | Not available yet |
| Uzbekistan (UZ) | Not available yet |
| Kyrgyzstan (KG) | Not available yet |
| Belarus (BY) | Not available yet |
| Moldova (MD) | Not available yet |
| Ukraine (UA) | Not available yet |
| Türkiye (TR) | Not available yet |
| United Arab Emirates (AE) | Not applicable |
| Albania (AL) | Not available yet |
| Angola (AO) | Not available yet |
| Argentina (AR) | Not available yet |
| Austria (AT) | Not available yet |
| Australia (AU) | Not available yet |
| Bosnia & Herzegovina (BA) | Not available yet |
| Bangladesh (BD) | Not available yet |
| Bulgaria (BG) | Built-in mechanism only |
| Bolivia (BO) | Not applicable |
| Brazil (BR) | Not available yet |
| Canada (CA) | Not available yet |
| Switzerland (CH) | Not available yet |
| Chile (CL) | Not applicable |
| China (CN) | Not applicable |
| Colombia (CO) | Not applicable |
| Costa Rica (CR) | Not applicable |
| Cyprus (CY) | Not available yet |
| Czechia (CZ) | Not applicable |
| Germany (DE) | Not available yet |
| Denmark (DK) | Not available yet |
| Dominican Republic (DO) | Not available yet |
| Ecuador (EC) | Not available yet |
| Estonia (EE) | Not available yet |
| Egypt (EG) | Not applicable |
| Spain (ES) | Not applicable |
| Ethiopia (ET) | Not available yet |
| Finland (FI) | Not available yet |
| France (FR) | Not available yet |
| United Kingdom (GB) | Not applicable |
| Ghana (GH) | Not available yet |
| Greece (GR) | Not available yet |
| Croatia (HR) | Not applicable |
| Hungary (HU) | Not available yet |
| Indonesia (ID) | Not available yet |
| Ireland (IE) | Not available yet |
| Israel (IL) | Not available yet |
| Italy (IT) | Built-in mechanism only |
| Jordan (JO) | Not applicable |
| Japan (JP) | Not available yet |
| Kenya (KE) | Not available yet |
| South Korea (KR) | Not applicable |
| Lithuania (LT) | Not available yet |
| Latvia (LV) | Not available yet |
| Montenegro (ME) | Not available yet |
| North Macedonia (MK) | Not available yet |
| Mongolia (MN) | Not applicable |
| Malta (MT) | Not available yet |
| Mexico (MX) | Not applicable |
| Malaysia (MY) | Not available yet |
| Mozambique (MZ) | Not available yet |
| Nigeria (NG) | Not available yet |
| Netherlands (NL) | Not available yet |
| Norway (NO) | Not available yet |
| Nepal (NP) | Not available yet |
| New Zealand (NZ) | Not available yet |
| Panama (PA) | Not available yet |
| Peru (PE) | Not available yet |
| Philippines (PH) | Not available yet |
| Pakistan (PK) | Not available yet |
| Poland (PL) | Not available yet |
| Portugal (PT) | Not applicable |
| Romania (RO) | Not available yet |
| Serbia (RS) | Not applicable |
| Rwanda (RW) | Not available yet |
| Saudi Arabia (SA) | Not applicable |
| Sweden (SE) | Not available yet |
| Singapore (SG) | Not available yet |
| Slovenia (SI) | Not applicable |
| Slovakia (SK) | Not applicable |
| Taiwan (TW) | Not available yet |
| Tanzania (TZ) | Built-in mechanism only |
| Uganda (UG) | Not available yet |
| United States (US) | Not applicable |
| Uruguay (UY) | Not available yet |
| Vietnam (VN) | Not applicable |
| Kosovo (XK) | Not available yet |
| South Africa (ZA) | Not available yet |
| Zambia (ZM) | Not available yet |
| Zimbabwe (ZW) | Not available yet |
In the three countries with a built-in mechanism, the evidence is limited to specific families:
- Bulgaria: Daisy Compact M 02, Bulgarian version. Its manual describes automatic daily Z reports and a time setting on the device. This does not extend to Georgian Daisy firmware.
- Italy: an approved ServerRT implementation under RT v11.2, §2.11. This does not establish a timer for every hardware RT or software cash register.
- Tanzania: the TRA EFD built-in mechanism. Ask an approved supplier how to configure your model; this finding does not extend to VFD or Zanzibar's regime.
Configuration of these mechanisms through the bridge has not been confirmed. Contact the register supplier with the exact model and firmware version. As of this snapshot, no countries allow automatic Z reports through the bridge either unconditionally or subject to the owner's consent.
Before you start#
- Check that the register is assigned to the correct location, and that the location's country and time zone are correct. Do not change the country to make a switch appear.
- Connect the register to the hardware bridge. The program must be running on the computer and support this feature. A saved setting does not prove that an older bridge can carry it out.
- The register must report its shift status and number. Closing before the limit also requires a known deadline. Missing information cannot be replaced by assuming that every register uses a 24-hour limit.
- Specify the person authorised to generate the report where country rules require one. “Automatic closing” is available as a label only where permitted; an arbitrary name cannot replace a responsible person.
- Assign someone to check the result and deal with failures. A powered-off computer, paper jam or device lockout may prevent a Z report.
How to enable it once your country and device are supported#
These steps are not available yet. Once the feature is released and approved for your country and model:
- Open Hardware, select the location's fiscal register, then open Shift & reports.
- In Automatic shift closing, turn on Close the shift automatically. If the section is missing, check availability above and contact support.
- Choose an available mode: Before the limit, with a margin of 15–240 minutes (initial value: 60); At a set time, using the location's time zone; or Whichever comes first. If the deadline is unknown, closing before the limit is unavailable.
- Check the cashier details for the Z report. If conditions and a consent checkbox appear, read and accept them: the author, time and terms version are recorded. Changed conditions may require new consent.
- Select Save, then check the status and next closing time. A message about an old program or missing schedule means you cannot rely on automatic closing.
The built-in mechanism follows a different procedure: configure and check it using the manual for the register's national version. Do not replace it with an external Z schedule.
Once approved, the bridge can run locally without an open admin panel or cloud connection, provided it has already received the setting. Internet access is needed to deliver cloud notifications and records. On startup after downtime, the bridge checks for a missed closing before the first sale, but this cannot clear a lockout requiring a person. A Z report is deferred while a receipt is unfinished.
What happens to the POS cash shift#
The fiscal shift, POS cash shift and employee shift are separate. A Z report alone does not prove that the cash drawer has been counted.
A location setting is provided for linking the fiscal Z to cash shifts:
- Record only (default): the cash shift stays open. The opening float, cash movements and expected balance remain unchanged. The cashier counts the cash and closes the shift as usual.
- Close the cash shift: after a successful automatic Z report, cash shifts that were already open at the location close without a cash count. This may affect several cashiers at the same location. The result is marked “Closed automatically, cash was not counted”; the actual amount and discrepancy must be recorded separately. A count for such a report is supported within 7 days, once only.
This link requires the cloud to receive the closing event and the corresponding update to be released. When offline, the POS record may arrive later; check the register's own state separately. Until approval and release, do not rely on a fiscal Z report to finish the cash shift automatically. For manual reconciliation, see Count cash, X report and closing the shift.
How to check the result#
After release and setup, check three things:
- Register: the shift is actually closed and a numbered Z report exists. An X report does not close a shift.
- Hardware → Shift & reports: recent closings show a successful outcome and who closed it — the program, a person or the register's timer. A scheduled time is not evidence of success.
- POS: check the cash shift and cash count. “Z automatically at …” is a plan; “Automatic Z failed — run it yourself” requires the cashier's attention. If the deadline is unknown, the absence of a warning does not guarantee that time remains.
If closing fails#
| Situation | What to do |
|---|---|
| Register or computer is off | Power on the equipment, check the connection and shift status. If the register is already locked, follow its recovery procedure. |
| A receipt is unfinished or paper has run out | Complete or properly cancel the unfinished receipt, resolve the error and check the shift status again. |
| “Result unknown” after a connection failure | Do not blindly send Z again. Check the register's status and last report. An unknown outcome is not retried automatically; contact support if you cannot establish the result. |
| Register closed, but POS has no record yet | Check the cloud connection. Do not issue a second Z just to create an interface record. |
| Russia: shift exceeded 24 hours | Follow the manual closing procedure. Automatic closing does not correct payments taken without a required receipt. |
Daisy, error 82 (“more than 24 hours without the daily report”): go to the register, press C, then generate a Z report using the normal procedure. Pressing C alone does not replace Z. Next, verify closure and the outcome of the original sale; retry the receipt only after checking that it was not already issued. After this lockout, software cannot complete recovery without a person at the register. Automatic closing for Georgian Daisy registers is not currently promised.
If the error remains, record the code, register model and firmware, and the time and number of the last Z report, then contact support. Do not try to bypass the lockout by changing the register's clock.