If the register requests a Z report, first identify the location's country and fiscal system. These four countries have different rules: there is no shared “24 hours after opening” deadline. This guide explains what to check and how to avoid repeating a command whose outcome is unknown.
Which session needs closing#
A fiscal session or fiscal day is the period whose totals are recorded by the register's or cash-register software's Z report. An X report shows current totals without closing it.
The POS cash shift records the float, cash in, cash out and cash count. Closing that shift, ending an employee's working day and issuing Z are separate actions. A printed POS cash report does not prove that the fiscal system has closed.
What you need#
- A location using a fiscal system to which Z applies, such as a shop, café or service business. This guide does not establish support for every business type or register.
- The exact model, national firmware or software version, closing instructions and the responsible employee's permissions.
- To issue a command from cenaly.com: a connected, supported device, a running bridge and access to the selected location's equipment. A country appearing here does not mean its driver is available.
- For any remote action: separately confirmed authority, an accepted closing method and a connection to the register. General permission remains unestablished for these countries.
Deadlines and consequences by country#
[P] means confirmed by the named primary source in the version examined. [U] means not confirmed by a primary source; “not established” means neither permission nor absence of an obligation. This is a help guide, not a legal opinion. Check whether older texts remain current and apply to your system.
| Country | Deadline and who sets it | Consequences of missing it | Remote closing by a person | Action at the device | Identity in the report |
|---|---|---|---|---|---|
| Greece (GR) | [P] AADE's December 2021 guide, p. 11: 24 hours from the first transaction after the last Z. This is not the session-opening time; the current text of the referenced rule was not separately obtained. | [P] ICS DELTA error 16 requires Z and confirmations; Citizen Fiscal II does not resume sales until journal files are transferred. [U] A separate fine for late Z is not established. | [U] Not established; check with the supplier/AADE. | [P] DELTA error 16 requires keys and a date/time check. Other models and states have their own procedure. | [P] AADE requires the register's registration number. [U] Whose name and whether a personal signature belongs in Z are not established. |
| Republic of Cyprus (CY) | [P] Κ.Δ.Π.224/2010: ΦΗΜ — end of the daily period with transactions; ΦΗΜΣ — a report for each calendar day with at least one transaction. | [P] Without the daily report, ΦΗΜΣ stops or issues the report itself. [U] Recovery for a particular model and a separate fine are not established. | [U] Not established; check with the supplier/tax authority. | [P] Simple ΦΤΜ/ΑΤ registers use keyboard commands. [U] The requirement for advanced registers and the normal PC-connected mode of ΦΗΜΣ is not established. | [P] The user's name or business name, address and device details. [U] This does not establish a cashier-name requirement; substitution with the owner's name is unconfirmed. |
| Malta (MT) | [P] The 2007 specifications describe daily Z for Types A/B/C. [U] A mandatory closing hour, midnight or a 24-hour limit is not established. | [U] A lockout and separate fine specifically for late Z are not established. | [U] Not established; check with the supplier/MTCA, and your actual authorisation for EXO. | [U] A key, PIN, Z mode and local confirmation depend on the actual model; the procedure is not established. | [P] The closing-chit specification lists receipt counts and amounts by rate/VAT. [U] A cashier field and the initiator's signature are not established. |
| France (FR) | [P] BOFiP §170: daily, monthly and annual closing for applicable cash-register software. This paragraph establishes neither an exact hour nor a universal 24-hour lockout. | [P] Immutable totals and original line-by-line records are required (§§170–180). [U] A separate penalty for one late Z is not established. | [U] Not established for an arbitrary system; check with the publisher/tax authority for the software version and user permissions. | [P] The examined Hiboutik procedure runs in a browser. [U] A universal rule for other systems is not established. | [P] BOFiP requires accumulated and summary totals. [U] These paragraphs do not establish a mandatory cashier name in Z; check your software's format. |
Northern Cyprus was not researched here. The BOFiP §170 exception for certain invoicing software does not extend to every French register. In Malta, a fiscal receipt book has no device Z, but its existence does not remove the closing requirement for a register actually in use.
Can a person close remotely#
The country-level answer is not established for each country ([U]). The following are confirmed technical distinctions, not permission to close remotely or a list of cenaly.com integrations.
- Greece: [P] CITIZEN CT-S601 with MCP V1.R2.T0 documents a PC procedure: Z generation and electronic-journal transfer with acknowledgement. Acceptance of the first command is not proof of completion; error
0x73requires the keyboard. Applicability to another model/firmware is not established [U]. After ICS DELTA error 16, follow the local procedure, including the date/time check [P]. - Cyprus: [P] Simple ΦΤΜ/ΑΤ registers provide keyboard-only command input. ΦΗΜΣ local controls are described for operation with the PC disconnected; this does not require a button press for every normal Z. A remote Z command for advanced models and ΦΗΜΣ is not established [U].
- Malta: [P] Type C has a host-computer interface. That interface alone does not prove Z can be issued without local action. A remote method for Types A/B/C and EXO is not established [U]; a cloud POS does not replace the terms of an EXO authorisation.
- France: [P] Hiboutik documents “Synthèses → Quotidienne” and browser-based day closing; early closing requires a separate permission. Closing is irreversible and also closes earlier unclosed days. This proves neither that late closing is lawful nor an external API or cenaly.com integration. Compliance evidence for the particular configuration was not independently checked [U].
What cenaly.com does today#
The updated web POS has a fiscal-session indicator when the bridge reports its state and the deadline is known. With up to two hours left it reminds the cashier to issue Z; with no more than one hour left it provides a separate warning when a person must close. An unknown deadline cannot produce a reliable countdown.
For a recognised refusal caused by an outstanding Z report, the receipt-failure dialog may offer “Take Z and retry receipt”. After your confirmation, it issues Z first and retries the same receipt only after a known success. If Z fails or its outcome is unknown, the receipt is not retried automatically. This is not scheduled automatic closing.
How to close and check the outcome#
- Select the location and register, and agree the closing with the cashier on duty. Complete or resolve any open receipt using the system's normal instructions.
- On the computer connected to the bridge, open Equipment → Devices → fiscal register → Open → Shift & reports. The same section opens in the web POS equipment window. If your model is unsupported, use the supplier's normal procedure.
- Check the status and last Z. Under Closing the shift, select Close shift (Z report) and confirm. An X report does not close the session.
- Wait for the result next to the buttons. The Z number, if returned by the register, helps you match the report. Refresh the status and check the paper roll or electronic journal; sending the command alone is insufficient.
- Count the cash separately and close the POS cash shift if your working procedure requires it.
If the receipt-failure dialog is already open, use the offered Z-and-retry action only after checking the cause and completing any required action at the device. If the outcome is unknown, stop and reconcile the documents before another attempt.
When the manager is away with a phone#
You can open the admin panel and select a location on a phone, but Shift & reports currently requires a connection to the local bridge. This tab is not a ready-to-use cloud closing button for an owner away from the premises.
The web POS Z action in the failure dialog has a cloud route to the location's bridge, but this is a separate scenario. Internet access, a running bridge, a supported register and user permissions are all required; that route removes neither local confirmation nor the need to establish legal permission.
For GR/CY/MT/FR, until your supplier/tax authority confirms the acceptability of your specific remote method, ask an authorised employee on site to close using the system's instructions. Do not change the location's country or cashier name to gain access to a button.
POS apps#
App updates include a prepared Cash register & terminal section with Z after confirmation: Android through More operations; Windows and Ubuntu through the device menu or shift window; iPad/Mac through the cash-operations menu. The Z-and-retry recovery flow has also been prepared.
Release of these app updates is not confirmed. Do not rely on the section until you check the installed version; a screen's presence establishes neither local-register support nor permission to close remotely.
Limitations#
Automatic closing by our software is hidden for these countries because sufficient grounds and conditions have not been confirmed. This is a service availability restriction, not a claim of an explicit legal prohibition. See automatic fiscal-session closing.
The interface language and domain do not change the location's country. One model's capabilities, browser access or the absence of a discovered prohibition cannot be extended to the whole country. A software warning does not replace the deadline in the instructions and applicable rules.
Troubleshooting#
| What you see | What to do |
|---|---|
| No indicator or time remaining | Check the version and bridge connection. The register may not report a deadline; absence of a warning is not permission to keep selling. |
| Register controls do not open on a phone | The equipment tab needs a local bridge. Contact the cashier; do not create a sale just to trigger a failure dialog. |
| ICS DELTA: error 16 | Follow the device instructions: local confirmations and a date/time check. Repeating a cloud command does not replace the keys. |
| No paper, cover open or keyboard required | An authorised employee resolves the cause on site. A remote command cannot replace physical action. |
| Command sent, no response | Do not blindly repeat Z or the receipt. Check the last Z, roll and journal; if the outcome remains unclear, contact the supplier/support. |
| Z exists but sales have not resumed | Check completion of the entire procedure: the examined Citizen, for example, requires journal transfer. Do not issue a second Z instead of completing the missing step. |
Frequently asked questions#
Is the limit always 24 hours? No. The examined Greek guide counts from the first transaction after Z; Cyprus distinguishes a daily period from a calendar day; France specifies frequency, while Malta's exact limit is not established [U].
Can the owner replace the cashier in the report? No general conclusion has been established for these four countries [U]. Use the details required by your system and applicable rules.
If no fine was found, can closing be late? No. A specific penalty for late Z is not established [U]; closing and record-retention obligations still apply.
Why are Italy, Spain and Portugal absent? Italy has a separate guide. Spain and Portugal fall outside this scenario under the regimes examined; this is not an exemption from accounting or other obligations.
Sources#
- Greece: AADE guide, December 2021, p. 11; CITIZEN CT-S601 MCP protocol. An archived guide does not establish that no later changes exist.
- Cyprus: Κ.Δ.Π.224/2010, §§2.7.12, 5.2.5, 5.7 and Part B §1.1: daily reporting, the ΦΗΜΣ calendar day and keyboard input for the simple type.
- Malta: VAT Act, CAP406, Thirteenth Schedule; Fiscal Cash Register Specifications of 27 April 2007. The full set of current amendments to the specification is unconfirmed [U].
- France: BOFiP, BOI-TVA-DECLA-30-10-30, §§170–180, 290; Hiboutik closing instructions. Publisher instructions confirm only that product's technical procedure.